- Home
- Products
- Hybrid inverters
- SPM 2500-6000TL-HU2 / SPM 3000-6000TL-HU
Growatt · from DAHAI SOLAR, authorised EU distributor
SPM 2500-6000TL-HU2 / SPM 3000-6000TL-HU
Single-phase hybrid inverter
2.5–6 kW
- single-phase
- 40–60 V battery
- lithium or lead-acid
- switch <10 ms
A single-phase hybrid inverter for houses, from 2.5 to 6 kW, for 40–60 V lithium or lead-acid batteries. In an outage it switches to backup in under 10 ms.
DAHAI SOLAR SRL is a first-tier authorised distributor of Growatt products for the EU market (certificate GRT298JZ19). About the Growatt authorisation
Specification
| Version | SPM 2500TL-HU2 | SPM 3000TL-HU2 | SPM 3600TL-HU2 | SPM 5000TL-HU2 | SPM 6000TL-HU2 | SPM 3000TL-HU | SPM 3600TL-HU | SPM 4000TL-HU | SPM 4600TL-HU | SPM 5000TL-HU | SPM 5500TL-HU | SPM 6000TL-HU |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Variant datasheet | HU2 | HU2 | HU2 | HU2 | HU2 | HU | HU | HU | HU | HU | HU | HU |
| Power steps | HU2: 2.5 / 3 / 3.6 / 5 / 6 kW · HU: 3 / 3.6 / 4 / 4.6 / 5 / 5.5 / 6 kW | |||||||||||
| AC nominal power | 2,500 W | 3,000 W | 3,600 W | 5,000 W | 6,000 W | 3,000 W | 3,600 W | 4,000 W | 4,600 W | 5,000 W | 5,500 W | 6,000 W |
| Max. AC apparent power | 2,500 VA | 3,000 VA | 3,600 VA | 5,000 VA | 6,000 VA | 3,000 VA | 3,600 VA | 4,000 VA | 4,600 VA | 5,000 VA | 5,500 VA | 6,000 VA |
| Max. output current | 10.9 A | 13.1 A | 15.7 A | 21.8 A | 26.1 A | 13.1 A | 15.7 A | 17.4 A | 20 A | 21.8 A | 24 A | 26.1 A |
| Nominal AC input power | 2,500 W | 3,000 W | 3,600 W | 5,000 W | 6,000 W | 3,000 W | 3,600 W | 4,000 W | 4,600 W | 5,000 W | 5,500 W | 6,000 W |
| Nominal input current | 10.9 A | 13.1 A | 15.7 A | 21.8 A | 26.1 A | 13.1 A | 15.7 A | 17.4 A | 20 A | 21.8 A | 24 A | 26.1 A |
| Max. grid passthrough current | 12.5 A | 15 A | 18 A | 25 A | 30 A | 16.6 A | 20 A | 22.2 A | 25.5 A | 27.7 A | 30.5 A | 33.3 A |
| Max. generator input power | 9,200 W | |||||||||||
| Grid nominal voltage | 220/230/240 V | |||||||||||
| Grid frequency | 50/60 Hz | |||||||||||
| Power factor | 0.8 leading … 0.8 lagging | |||||||||||
| THDi | <3% | |||||||||||
| Max. recommended PV power | 4,000 W | 4,800 W | 5,760 W | 8,000 W | 9,600 W | — | — | — | — | — | — | — |
| Max. PV access power | — | — | — | — | — | 6,000 W | 7,200 W | 8,000 W | 9,200 W | 10,000 W | 11,000 W | 12,000 W |
| Max. PV input power | — | — | — | — | — | 4,500 W | 5,400 W | 6,000 W | 6,900 W | 7,500 W | 8,250 W | 9,000 W |
| Max. input power per MPPT | HU2: — · HU: 4,500 W | |||||||||||
| DC AC ratio | HU2: 1.6 (page-1 bullet) · HU: 1.5 (page-1 bullet) | |||||||||||
| Maximum DC input voltage | HU2: 550 V · HU: 600 V | |||||||||||
| PV start voltage | HU2: 70 V · HU: 130 V | |||||||||||
| MPPT voltage range | HU2: 80–525 V · HU: 150–550 V | |||||||||||
| MPPT trackers | 2 | |||||||||||
| PV strings per MPPT | 1 | |||||||||||
| Max. input current per MPPT | HU2: 18 A · HU: 22 A | |||||||||||
| Max. short circuit current per MPPT | 27.5 A | |||||||||||
| Battery | 40–60 V, lithium or lead-acid | |||||||||||
| Battery voltage range | 40–60 V | |||||||||||
| Battery type | Lithium battery / Lead-acid battery | |||||||||||
| Max. charge discharge current | 60 A | 70 A | 90 A | 120 A | 140 A | 70 A | 90 A | 100 A | 110 A | 120 A | 130 A | 140 A |
| Continuous charge discharge power | 2,500 W | 3,000 W | 3,600 W | 5,000 W | 6,000 W | 3,000 W | 3,600 W | 4,000 W | 4,600 W | 5,000 W | 5,500 W | 6,000 W |
| Backup power | 2,500 W | 3,000 W | 3,600 W | 5,000 W | 6,000 W | 3,000 W | 3,600 W | 4,000 W | 4,600 W | 5,000 W | 5,500 W | 6,000 W |
| Backup voltage | HU2: 220/230/240 V · HU: 230 V single phase | |||||||||||
| Backup frequency | 50/60 Hz | |||||||||||
| Switch to backup | <10 ms | |||||||||||
| Backup overload | HU2: 200% full load @ 10 s · HU: 200% full load @ 5 s | |||||||||||
| Peak efficiency | HU2: 97.5 % · HU: 98.1 % | |||||||||||
| European efficiency | HU2: 96.6 % · HU: 97.6 % | |||||||||||
| MPPT efficiency | 99 % | |||||||||||
| Protection | PV switch / AC over current protection / AC over voltage protection / Ground fault monitoring / Grid monitoring / Anti-islanding protection / Residual-current monitoring unit / Insulation resistance monitoring / Surge protection: DC Type II / AC Type II | |||||||||||
| AFCI | HU2: optional · HU: not listed | |||||||||||
| Units in parallel | HU2: up to 9 units · HU: up to 6 units | |||||||||||
| Three phase system | can form a 400 V three-phase system (page-1 bullet, both datasheets) | |||||||||||
| Applications | DC-coupled, AC-coupled, AC-retrofit (page-1 bullet, both datasheets) | |||||||||||
| Generator | charge from diesel generator (page-1 bullet, both datasheets) | |||||||||||
| Dimensions | HU2: 345 × 450 × 255 (W × H × D) · HU: 330 × 580 × 232 (W × H × D) | |||||||||||
| Weight | HU2: 16 net / 20 gross · HU: 26 kg | |||||||||||
| Operating temperature | -25 to +60 (derating above 45) | |||||||||||
| Noise | HU2: — · HU: ≤30 dB(A) typical | |||||||||||
| Self consumption | HU2: — · HU: <60 W | |||||||||||
| Topology | transformerless | |||||||||||
| Cooling | HU2: smart fan cooling · HU: natural | |||||||||||
| Protection rating | HU2: IP66 · HU: IP65 | |||||||||||
| Relative humidity | 0–100% | |||||||||||
| Maximum altitude | <2000 m | |||||||||||
| Display | LCD touch screen | |||||||||||
| Communication | HU2: RS485/CAN/USB; Wi-Fi · HU: RS485/CAN/USB; Wi-Fi/LAN | |||||||||||
Figures from Growatt's datasheet. The datasheet in force prevails.
Highlights from the datasheet
- UPS function, 10ms transition
- 1.6 DC/AC ratio with 2 MPPTs (HU2)
- 1.5 DC/AC ratio with 2 MPPTs (HU)
- Up to 140A charging/discharging current
- Support DC-coupled, AC-coupled, AC-retrofit applications
- Type II Surge protection for DC and AC sides
- Support charge from diesel generator
- Support up to 9 units in parallel (HU2)
- Support up to 6 units in parallel (HU)
- Support form a 400V three-phase system
Warranty
5 years (HU2 datasheet); 10 years (HU datasheet)
Certificates and standards
- IEC 62116 (HU2 + HU)
- IEC 61727 (HU2 + HU)
- CE (HU2)
- IEC 61683 (HU2)
- IEC 60068 (HU2)
- NRS097 (HU2)
- EN 61000 (HU2)
- EN50549 (HU)
- CE-EMC (HU)
- CE-LVD (HU)
Certificate PDFs on request: we send them with every quote.
Request a quote for SPM 2500-6000TL-HU2 / SPM 3000-6000TL-HU
Tell us how many and where. We'll send the offer with the datasheet and the certificates.
DAHAI SOLAR S.R.L. · Oltenița, jud. Călărași · CUI 48970762
Quote for SPM 2500-6000TL-HU2 / SPM 3000-6000TL-HU
-
Growatt
29.9–50 kW
WIT 29.9/30/36/40/50K-XHU
Three-phase hybrid inverter for C&I, 29.9–50 kW
- three-phase
- 4 MPPT
- 3 battery inputs, 200–900 V
- IP66
Warranty 5 / 10 years: Yes/Opt
See the details · WIT 29.9/30/36/40/50K-XHU Request a quote · WIT 29.9/30/36/40/50K-XHU
-
Growatt
50–100 kW
WIT 50/63/75/100K-HU
Three-phase hybrid inverter for C&I, 50–100 kW
- three-phase
- 7–10 MPPT
- 600–1000 V battery
- IP66
Warranty 5/10 years: Yes/Opt
See the details · WIT 50/63/75/100K-HU Request a quote · WIT 50/63/75/100K-HU
-
DAHAI
3–8 kW
HyS-3/3.6/4/4.6/5/6/8K
HyS single-phase hybrid inverter
- single-phase
- 48 V battery
- IP66
See the details · HyS-3/3.6/4/4.6/5/6/8K Request a quote · HyS-3/3.6/4/4.6/5/6/8K
-
DAHAI
3–6 kW
HyS-3/3.6/5/6K-E
HyS-E single-phase hybrid inverter (Pro)
- single-phase
- AFCI option
- −40 °C
- IP66
See the details · HyS-3/3.6/5/6K-E Request a quote · HyS-3/3.6/5/6K-E